The rated capacity of this oil immersed power transformer is 650kVA 1250kVA 2000kVA. It can be used outdoors or installed inside substations.
The models that can be selected for oil immersed transformers include S9, S11, S13, S15, and so on.
The high-voltage part of oil immersed transformers can also be selected from 6KV, 6.3KV, 10KV, 10.5KV, 11KV, 20KV, 25KV, 33KV, 35KV, and so on
The low voltage part of oil immersed transformers can also be selected: 400V, 415V, 0.4KV, etc. It can be configured according to the actual situation in your local area.
650kVA 1250kVA 2000kVA oil-immersed transformer appearance



Rated Power (kVA) | High Voltage (kv) | Low Voltage (kv) | Connection symbol | No-load loss(W) | On-load loss(W) | No load current (W) |
30 | 6KV 6.3KV 10KV 10.5KV 11KV 20KV 35KV (customizable) | 0.4KV (customizable) | Ydn11 Yyn0 (customizable) | 100 | 600/630 | 2.1 |
50 | 130 | 870/910 | 2.0 | |||
63 | 150 | 1040/1090 | 1.9 | |||
80 | 180 | 1250/1310 | 1.8 | |||
100 | 200 | 1500/1580 | 1.6 | |||
125 | 240 | 1800/1890 | 1.5 | |||
160 | 280 | 2200/2310 | 1.4 | |||
200 | 340 | 2600/2730 | 1.3 | |||
250 | 400 | 3050/3200 | 1.2 | |||
315 | 480 | 3650/3830 | 1.1 | |||
400 | 570 | 4300/4520 | 1.0 | |||
500 | 680 | 5150/5410 | 1.0 | |||
630 | 810 | 6200 | 0.9 | |||
800 | 980 | 7500 | 0.8 | |||
1000 | 1150 | 10300 | 0.7 | |||
1250 | 1360 | 12000 | 0.6 | |||
1600 | 1640 | 14500 | 0.6 | |||
2000 | 2020 | 17820 | ||||
2500 | 2380 | 20700 |
(↓If you have other product needs, please click here to ask me)

The iron core is made of brand new and excellent silicon steel sheets.
Ensure that customers maintain low wear and tear during use, low noise during operation, and more energy-efficient requirements

Use heat-resistant enameled wire.
Ensure good conductivity, stable operation, enhanced overload capacity, low line loss, and resistance to oxidation of the winding.
Extend the lifespan of transformers

The transformer oil tank is composed of corrugated walls that can breathe.
Excellent corrugated walls can compensate for changes in transformer oil volume caused by temperature rise and fall. Therefore, we cancelled the design of the oil storage tank for the transformer. This not only reduces the cost of the transformer, but also lowers the overall height of the transformer. Saved users' various costs.

We will equip the transformer with sensitive relief valves and precise glass thermometer sockets.
Of course, we can also equip trip terminals with alarms and gas relays according to customer requirements.
Everything is just to ensure your safety during use.

Four production workshops
Due to the independent control of all aspects of our company, we can achieve economic benefits for our products. We ensure that each product is not only of high quality, but also very cheap.