LBS-33
                        High Voltage Circuit Breakers
                        Electric & Manual Type
                        Sf6
                        Fixed
                        Lbs
                        Rockwill
                        Wooden
                        China
                        8535210000
                        
                        Product Description
                    
                                
                        KEMA TEST REPORT

Summary
Pole-mounted load break switch(pole-LBS) applies up to 36KV 400/630A, 50Hz pole-LBS associated with a state of the art controller. This SF6 gas-insulated switch can corporate with the distribution automation system, and also isolate a faulted section of distribution line from the control center.
A simple pole-mounting arrangement contribute to quick and low cost installation, and the switch can be operated manually with a electronic controller. Electronic controller is contained in a stainless steel cabinet for an all weather environmental conditions. Remote monitoring and control can also be provided mounting wire or wireless modem in a cabinet.
Standard service condition
It shall be principal that this SF6 Gas Load Break Switch shall be used in the following service condition:
Ambient temperature
Short period peak value:50ºC
Average over a period of 24 hours: 40ºC
Lower limit over 24 hours: -25ºC
Relative humidity: 100%
Maximum altitude:1,000 meter
Features
 





 
                    
                
Summary
Pole-mounted load break switch(pole-LBS) applies up to 36KV 400/630A, 50Hz pole-LBS associated with a state of the art controller. This SF6 gas-insulated switch can corporate with the distribution automation system, and also isolate a faulted section of distribution line from the control center.
A simple pole-mounting arrangement contribute to quick and low cost installation, and the switch can be operated manually with a electronic controller. Electronic controller is contained in a stainless steel cabinet for an all weather environmental conditions. Remote monitoring and control can also be provided mounting wire or wireless modem in a cabinet.
Standard service condition
It shall be principal that this SF6 Gas Load Break Switch shall be used in the following service condition:
Ambient temperature
Short period peak value:50ºC
Average over a period of 24 hours: 40ºC
Lower limit over 24 hours: -25ºC
Relative humidity: 100%
Maximum altitude:1,000 meter
Features
- rugged switch
 - drivepipe with large diversity
 - quick operation
 - inflation valve
 - high pressure relief alarm
 - HD gas-pressure meter
 - Manual locking device
 - Low pressure warning device
 - Visible open/close status
 - Cintact position indicator
 - Manual operation on ground
 - To provide one-stop service, please consult!
 
| Product mode | RPS-15 | RPS-24 | RPS-38 | ||
| Rated voltage | KV | 15 | 24 | 38 | |
| 6/12/17.5 | 25.8 | 36 | |||
| Rated frequency | Hz | 50/60 | 50/60 | 50/60 | |
| Lightning impulse withstand voltage | KV | 110 | 125 | 200 | |
| Power frequency withstand voltage 1min | Dry | KV | 50 | 75 | 110 | 
| wet | 40 | 60 | 95 | ||
| Rated current | A | 400/630 | |||
| Peak withstand current | KA | 50 | 50 | 50 | |
| Rated short time making current | KA | 20 | 20 | 20 | |
| Rated short time withstand current | KA/S | 20/4 | 20/4 | 20/4 | |
| Rated cable charging breaking current | A | 10 | 16 | 20 | |
| Rated line charging breaking current | A | 1 | 1.5 | 2 | |
| Rated closed-loop breaking current | A | 400/630 | |||
| Rated current breaking times | Times | ≥400 | |||
| Rated working pressure | Mpa | 0.05 | |||
| Per-phase main circuit resistance | uΩ | ≤80 | |||
| Relative gas leakage rate | Year | ≤1% | |||
| Operation of mechanical stability | Times | 6000 | |||
| weight | kg | 115 | 125 | 135 | |
| Institutions boxes and controller protection class | IP67 | ||||
| Type of mounting | The lifting type(suspended)/block(horizontal) | ||||