• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
30~80kv Ultra-Low Frequency High Voltage Generator 0.1Hz Vlf AC Generator Electric Power Vlf Hipot Tester Low Frequency Cable Test Vlf 60kv图130~80kv Ultra-Low Frequency High Voltage Generator 0.1Hz Vlf AC Generator Electric Power Vlf Hipot Tester Low Frequency Cable Test Vlf 60kv图230~80kv Ultra-Low Frequency High Voltage Generator 0.1Hz Vlf AC Generator Electric Power Vlf Hipot Tester Low Frequency Cable Test Vlf 60kv图330~80kv Ultra-Low Frequency High Voltage Generator 0.1Hz Vlf AC Generator Electric Power Vlf Hipot Tester Low Frequency Cable Test Vlf 60kv图430~80kv Ultra-Low Frequency High Voltage Generator 0.1Hz Vlf AC Generator Electric Power Vlf Hipot Tester Low Frequency Cable Test Vlf 60kv图530~80kv Ultra-Low Frequency High Voltage Generator 0.1Hz Vlf AC Generator Electric Power Vlf Hipot Tester Low Frequency Cable Test Vlf 60kv图6

30~80kv Ultra-Low Frequency High Voltage Generator 0.1Hz Vlf AC Generator Electric Power Vlf Hipot Tester Low Frequency Cable Test Vlf 60kv

Price $3999.00
Min Order 1 Piece  
Shipping from Hubei, China
Quantity
-+
Product details
KDVLF
Yes
1 Year
<500mm
<900kg
Universal Testing Machine
<1000KN
0.5
Electronic Load
Dynamic Load
Needle
Computer Control
0-100Kg
AC220V
Under
Capacitive Touch Screen, Automatic Storage,etc
Ultra Low Frequency High Voltage Generator
≤ 5%
≤ 3%
0.1Hz, 0.05Hz, 0.02Hz
OEM, ODM, Obm, Software Reengineering
≤ 10ms
30kv, 40kv, 50kv, 60kv, 80kv, 90kv, etc
3%
Overvoltage Protection, etc
Electronic
KDZD
Wooden Case
25*28*40cm
Hubei, China
9030332000
Product Description
Product Description

 


Product parameters
Product Name
Ultra Low Frequency High Voltage Generator
Rated voltage
30kV, 40kV, 50kV, 60kV, 80kV, 90kV, etc
Measurement accuracy
3%
Voltage waveform distortion
 ≤ 5%
Voltage positive and negative peak error
 ≤ 3%
Output frequency
0.1Hz, 0.05Hz, 0.02Hz

Product Features

★Current, voltage, and waveform data are directly obtained through high-voltage side sampling, so the data is true and accurate
Overvoltage protection: When the output exceeds the set voltage limit, the instrument will shut down for protection, with an action time of less than 20 milliseconds
Overcurrent protection: designed as a dual protection of high and low voltage, the high voltage side can be precisely shut down for protection according to the set value; When the current on the low-voltage side exceeds the rated current, shutdown protection will be implemented
★The high-voltage output protection resistor is designed inside the boost, so there is no need to connect another protection resistor externally
★For products with a voltage of over 50kv, the series combination method can achieve multiple uses for one machine, making it extremely convenient to use
★Due to the use of high and low voltage closed-loop negative feedback control circuit, there is no capacitance rise effect in the output
★Measurement accuracy: 2%                                  
★Voltage positive and negative peak error: ≤ 3%
★Voltage waveform distortion: ≤ 5%                      
★Output frequency: 0.1Hz, 0.05Hz, 0.02Hz
★Power supply: AC 50Hz, 220V ± 5% (generator: AC 50Hz, 220V ± 5%)
★Test time: Handover: 60 minutes    
★Prevention: 5 minutes (can run for a long time)
 
Model noOutput
Voltage/
Current
(Peak)
Load CapacityControl UnitBooster(Tank)Power 
Capacitance/
Freuency
Net Dim.
(cm)
Net Wt
 (kg)
Net Dim.
(cm)
Net Wt
(kg)
KDVLF-40 40kV/20mA0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
40×31×20  629x15×35251200W
KDVLF-50 50kV/20mA0.1Hz-0.01Hz
Auto Variable
Capacity:≤10µF
40×31×20  629x15×35251500W
KDVLF-60 60kV/59mA0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 60kV;
40×31×20  645×19×36452000W
KDVLF-80 80kV/59mA0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 80kV;
Capacity:10µF for single booster (40/40kV)
40×31×20  629x15×35    253000W
36x19×45    45
KDVLF-90 90kV/59mA0.1Hz-0.01Hz
Auto Variable
Capacity:5µF at 90kV;
Capacity:10µF for single
booster (40/50kV)

40×31×20
 
  629x15×35    253500W
36x19×45    45
                                       
Function comparison of VLF series models
 
Output
(Peak)
StructureModel noAC Withstand Voltage TestTan Delta TestPD TestCapacity
(μF)
Insulation
Resistance
Test (IR)


30KV

1*Controller
1*30KV Booster
1*Capacitor
KDVLF-30XXXX
KDVLF-30AX
KDVLF-30BXX
KDVLF-30C


40KV

1*Controller
1*40KV Booster
1*Capacitor
KDVLF-40XXXX
KDVLF-40AX
KDVLF-40BXX
KDVLF-40C


50KV

1*Controller
1*50KV Booster
1*Capacitor
KDVLF-50XXXX
KDVLF-50AX
KDVLF-50BXX
KDVLF-50C

60KV
1*Controller
1*60KV Booster
1*Capacitor
KDVLF-60XXXX
KDVLF-60AX
KDVLF-60BXX
KDVLF-60C

70KV
1*Controller
1*30KV Booster
1*40KV Booster
1*Capacitor
KDVLF-70XXXX
KDVLF-70AXX


80KV
1*Controller
1*30KV Booster
1*50KV Booster
1*Capacitor, or

1*Controller
2*40KV Booster
1*Capacitor
KDVLF-80XXXX
KDVLF-80AX
KDVLF-80BXX
KDVLF-80C


90KV

1*Controller
1*40KV Booster
1*50KV Booster
1*Capacitor
KDVLF-90XXXX
KDVLF-90AX
KDVLF-90BXX
KDVLF-90C
Note:  DC leakage current measurement for buyer's option (any type can add this function if required).


Buyer review
Loading review details...
Contact

Wuhan Kaidi Zhengda Electric Co., Ltd.

Audited Supplier1 Year
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

Recommended for you