• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
2p 4p 30mA 16A 63A 100A 240V Typeb RCCB for AC EV Charger图12p 4p 30mA 16A 63A 100A 240V Typeb RCCB for AC EV Charger图22p 4p 30mA 16A 63A 100A 240V Typeb RCCB for AC EV Charger图32p 4p 30mA 16A 63A 100A 240V Typeb RCCB for AC EV Charger图42p 4p 30mA 16A 63A 100A 240V Typeb RCCB for AC EV Charger图52p 4p 30mA 16A 63A 100A 240V Typeb RCCB for AC EV Charger图6

2p 4p 30mA 16A 63A 100A 240V Typeb RCCB for AC EV Charger

Price $55.00
Min Order 60 Pieces  
Shipping from Jiangsu, China
Quantity
-+
Product details
AG-VDF-2B-80A
Low Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
SF6
Insert
ELCB
1
Circuit Breaker
RCCB
CE, CB, CCC
Electro-Magnetic Type
AC 230(240)/400(415)
4000 Cycle
IP20
19mm
Screw Terminal
10000 Pole/Poles Per Month
AEGEN
Carton
36*78*81mm
China
8538900000
Product Description
2p 4p 30mA 16A 63A 100A 240V Typeb RCCB for AC EV Charger
Product Description

Residual current circuit breakers (RCCBs) 

This device is essentially a  attached to it. So basically it will only break the circuit when there is a leakage current flowing to earth. The tripping time is such as to minimise the risk to human life.

RCCBs usually have a fault making and . This means that they can handle a fault of 1 kA on their own if it is a fault to earth.

Type B residual current device disconnects the power if the earth leakage current is detected as dangerous. If the earth leakage current is equal to or less than 10mA, then the Type B residual current devices would not trip because this current amount is not dangerous. The electric car will continue to get charging without any interruption. The Type B residual current devices will immediately trip the circuit and disconnect the power supply for higher currents. Like this, Type B residual current devices will protect the circuits from danger.
                                                                        Technical Data
Model:AG-VDF-2B-63A
Pole No.:1P+N, 3P+N
Rated current(A):16A,25A, 32A, 40A, 63A,80A,100A 
Rated working voltage(I n):30, 100, 300, 500mA
Rated voltage(V):AC 230(240)/400(415)
Rated frequency(Hz):50/60
Rated making and breaking capacity:500(In=25A,32,40A), 630(In=63A)
Rated conditional short-circuit current Inc:10000A
Rated conditional residual short-circuit Current I c:10000A
Rated residual non operating current I no:0.5I n
Residual operating current range:0.5I n~I n
Operating time:≤0.3s
Type:A and AC type
Rated short-circuit breaking capacity:10000A
Mechanical life:2000 times
Degree of protection:IP20
Products name:Type B RCD | Type B RCCB | Detection residential RCCB 