• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
250 Kw 312.5 kVA Cost Effective Gas Generator with CHP System图1250 Kw 312.5 kVA Cost Effective Gas Generator with CHP System图2250 Kw 312.5 kVA Cost Effective Gas Generator with CHP System图3250 Kw 312.5 kVA Cost Effective Gas Generator with CHP System图4250 Kw 312.5 kVA Cost Effective Gas Generator with CHP System图5250 Kw 312.5 kVA Cost Effective Gas Generator with CHP System图6

250 Kw 312.5 kVA Cost Effective Gas Generator with CHP System

Price $32857.00
Min Order 1 Piece  
Shipping from Shandong, China
Quantity
-+
Product details
YDNC
1 Year
AC Three Phase
Gas
CE, ISO
>200kW
Standard
FAW
220/380V
1500/1800rpm
50/60Hz
CE ISO Saso
Ydn/Leroy-Somer/ABB
Electric Start
YDNPOWER
for Open Type, Packing with Plywood Case; for Sile
gas engine
Weifang China
8502110000
Product Description
 
ModelYDNCA-250
Rated power (kW/KVA)250/312.5
Rated current (A)450
container type Size (mm)6000*2500*2750
Weight (kg)6500
EngineModelFAW CA6SM3
TypeWater-cooled, 4-stroke,6 cylinder in-line
Rated Power(kW/KVA)290
Rated Speed(rpm)1500
Cylinder No.6
Bore*Stroke(mm)126.5×166
Cooling MethodWater-cooled
Oil Consumption(g/KWH)1
Oil Capacity(L)35
Cooling Water Capacity(L)110
Gas Consumption(kWh/m3)≤0.33
Starting method24V DC
AlternatorBrandFarrand
ModelFLD250
Rated Power(kW/KVA)250/312.5
Efficiency92.5%
Voltage Regulation<=±1
Excitation modeBrushless, Self Excitation
Insulation ClassH
Control 
System
ModelSMARTGEN HGM6110N
Working VoltageDC8.0V to DC35.0V
Overall Dimensions197 mm x 152 mm x 47mm
Panel Cutout186mm x 141mm
Working ConditionTemperature: (-25~70)ºC; Humidity: (20~90)%
Weight0.56kg
Special notes:
The definition of generator power is as follows:
Rated Power (PRP):
1. The running time is unlimited every year.
2. In a 250 hours continuous period, the average load rate should not exceed 70% .

Requirements for natural gas:

  1.  The methane content should not be lower than 95%.
  2.  The gas temperature should be between 0-40 ºC.
  3.  No impurity should be in the gas. Water in the gas should be less than 20g/Nm3.
  4.  Heat value should be at least 8500kcal/m3, if less than this value, the power of the engine will be declined.
  5.  Gas pressure should be 3-100KPa, if the pressure is less than 3KPa, booster fan is necessaryand pressure relief device should be added if the value is higher than 100KPA;  
  6.  The gas should be dehydrated and desulfurized. Make sure that there is no liquid in the gas. H2S<200mg/Nm3.


Buyer review
Loading review details...
Contact

Weifang Yidaneng Power Co., Ltd.

Audited Supplier6 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

Recommended for you