Product Description
Description of 200mm Standard powder Grading Lab mechanical test sieve shaker
Vibrating test sieve is recommended for general laboratory use and for the fine sieving of size particles.
It enjoys the following advantages:
1. Typically requires 50-150g of sample material
2. Setting time limits for 1 second -9999 seconds
3. Up to 9 fractions in one sieving operation
4. One person can pick up it
5. Approved ISO 9001:2008, CE and BV certificates
It enjoys the following advantages:
1. Typically requires 50-150g of sample material
2. Setting time limits for 1 second -9999 seconds
3. Up to 9 fractions in one sieving operation
4. One person can pick up it
5. Approved ISO 9001:2008, CE and BV certificates
Technical Parameters
No. | Item | Unit | Data | |
1 | Sieves | Layer | 1-8 layer as requested | |
2 | Diameter | mm | 200 | |
3 | Granularity | mm | 0.038-3 | |
4 | Noise | db | Less than 50 | |
5 | Feed capacity(once) | G | Less than 200g | |
6 | Vibration amplitude | mm | 5 | |
7 | Vibration motor | Voltage | V | 220-240 |
Rotate speed | Rpm | 1400 | ||
Power | KW | 0.12 | ||
8 | Overall dimension (length*width*height) | mm | 300*360*736 | |
9 | Net weight | kg | 37 |




Before usage please note that
a. Turn off power supply when the machine is not in use for an extended period of time.
b. Clean the sieves after operation, so they will be ready for use next time.
c. Do not splash water on the machine to avoid current leakage.
d. Turn the machine off immediately in the event of unusual noises and inspect for blockage or other irregularities.
e. Always ensure the lock nut are securely tightened before operation.
How to operate for getting good analysis result?
Step 1 | Weighing the tested material |
Step 2 | Place sieves with required mesh on the machine base sequentially |
Step 3 | Pour the tested material into the top of sieve |
Step 4 | The above step is OK, then cover with the lid and set the right time |
Step 5 | Power on |
Step 6 | It's time to set up, power off |
Step 7 | Remove the lid and sieves one by one from the top to bottom |
Step 8 | Summary: measure the weight of test material leaved on each sieve and bottom pan, and then gets their proportion and other related analysis result. |