ZD-DPA-X/X-100W
Signal Jammer
Wireless
CDMA
Data
New
Customized
24V-30V
N-F
1dBm
1.5dB
ZD TECH
by Box
23x26x20cm
China
8543209090
Product Description



| Item | Parameter | Unit | Remarks | |||
| Operating Voltage | 28 | V | 24-30V | |||
| Conversion efficiency | ≥42% | % | @100W typical | |||
| Controllable output power | 10W~100W | W | Software set power level | |||
| ALC power adjustment range | ≥30 | dB | Voltage Controlled Attenuation | |||
| gain | 50±1.0 | dB | ||||
| In-band fluctuation | ≤2.5 | dB | peak-to-peak | |||
| spurious emission | In working band | ≤-15dBm/1MHz | dBm | Measured when the center frequency plus CW signal to the maximum output power | ||
| out of work band | 9KHz~1GHz | No higher than normal noise floor clutter | dBm | |||
| 1G~12.75GHz | dBm | |||||
| Maximum allowable input power | ≥+10dBm | dBm | Lasts 1min without damage | |||
| Input VSWR | ≤1.35 | Add +28V, standard network output -10dBm | ||||
| Output VSWR | ≤1.30 | No power, standard network output -10dBm | ||||
| ≤1.35 | Power On, Dual Directional Coupler Test | |||||
| High and low temperature test | Working ambient temperature (ºC) | -10~+65 | ºC | Low temperature can start, monitoring works normally | ||
| Gain Stability | ±1.5 @-40ºC~+65ºC | dB | ||||
| power stability | ±1 @-40ºC~+65ºC | dB | ||||
| Power Requirements | ≥8A @+28Vdc; | CW output 100W | ||||
| Power supply interface, monitoring interface RS485 | 7W2 | Male | ||||
| RF output connector | N-F connector | |||||
| LCD liquid crystal display | Display frequency, power, switch status | |||||
| with 3 LED lights | POWER: Power indication; RUN: Running indication; ALARM: Alarm indication; | |||||
| Built-in cooling fan | Modules can be run separately | |||||
| physical dimension | 155 x 125 x 60mm | |||||
| Weight | 1.6Kg | |||||
| Appearance (how to use) | Black integrated module with fan (single or portable use) | |||||
| Monitoring | Function Description | Remarks | |
| Amplifier part setting parameters | Amplifier switch | Turn the amplifier on or off | |
| Alarm switch | Enable and disable the alarm function | ||
| Downlink Power Control | The maximum output power of the power amplifier can be set, the adjustment range is ≥20dB, and the high, medium and low power levels can be set | ||
| Amplifier over temperature alarm | The high temperature power amplifier shutdown threshold can be set, the power amplifier temperature exceeds 85 degrees, it will automatically shut down; 65 degrees will automatically restore | ||
| Amplifier overpower alarm | The actual power value is 2dB higher than the downlink ALC start control threshold and close | ||
| Power amplifier standing wave alarm | When the standing wave detection of the power amplifier is greater than 4, the power amplifier is automatically turned off | ||
| Amplifier overcurrent alarm | When the detection current of the power amplifier exceeds 12A, the power amplifier is automatically turned off | ||
| Amplifier under-power alarm | When the power amplifier detection power is less than 37dBm, an under-power alarm is displayed | ||
| Amplifier overvoltage alarm | When the power amplifier voltage exceeds 32V, the power amplifier will automatically shut down | ||
| Amplifier part query parameters | Amplifier switch status | If the power amplifier is set to "OFF", the query should be the state of the power amplifier off; otherwise, the state of the power amplifier will be turned on. | |
| Downstream output power level value | Detect power amplifier output power value, detection range (Pomax+2, Pomax-20) | Detection accuracy:Pout±1dB | |
| Downward standing wave ratio | The standing wave is normally 1.2, when the load is mismatched, the query value is 4.0 | ||
| temperature query | Detect the internal temperature of the module, detection range: -40ºC~+100ºC | detection error:±3ºC | |
| ALC value query | The displayed value is equal to the actual set ALC value | ||
| Voltage detection | Detection module working voltage | ||
| Current Detection | Detection module operating current | ||
| Signal generator settings | Frequency setting mode 1 | Any single frequency point setting within the range | The frequency setting accuracy is 1M, the maximum frequency bandwidth is 500M, and the maximum is 6G |
| Frequency setting mode 2 | Set the broadband frequency sweep mode, parameters such as frequency, interval, and step can be set | ||
| Frequency setting mode 3 | Set any 4 sub-frequency segments within the bandwidth, and a single sub-segment needs to be incremented | ||
| module communication | RS485 | ||
| Interface definition | +:28V,-: GND; control bit 1:485A,2:485B | ||