WWS20-48
Yes
3 Years
New
API, ISO, CB, CE
Collector Controller, Solar System Controller, Charger Controller, Wind Controller
48V/120V
48V/120V
58V
42A
1kw,2kw,3kw,5kw
<65mA
11kg
CE/TUV
Bessent
Carton
445*425*170mm
Jiangsu
Product Description
Detail Images



Model Specification
Parameters
Troubleshooting
Company Profile


Certification



Model Specification| Product Name | Rated Input Power | Rated Battery Voltage | Optional Function | Feature | |
| WWS | Wind solar hybrid controller | 0.6KW | 24V | Normal | Normal |
| 1KW | 48V | Low Voltage Charge | RS232 | ||
| 2KW | 96V | Buck Voltage Charge | RS485 | ||
| 3KW | 120V | Economic | Solar Dumpload Separately | ||
| 5KW | 192V | Micro-current Charge | Wind Turbine Single Phase DC | ||
| 10KW | 220V | RS232 Wind Turbine Single Phase DC, RS232 | |||
| 20KW | 240V | RS485 Wind Turbine Single Phase DC, RS232 | |||
| Parameters | WWS20-48 |
| Rated Battery Voltage | 48V |
| Rated Wind Turbine Input Power | 2KW |
| Maximum Wind Turbine Input Power | 3KW |
| Wind turbine brake current | 42A |
| Rated solar Input Power | 600W |
| Charge Shutoff Voltage | 58V |
| Stand by power loss | ≤65mA |
| Display mode | LCD |
| Cool mode | Fan |
| Protections | |
| Reverse battery protection | Anti-reverse-connection protection device in the inside of controller. |
| Open circuit protection | The controller will not be demaged if the battary in open circuit. |
| Solar anti-charge protection | Battery don't charge PV board in reverse. |
| Solar anti-reverse protection | The controller will not be damaged when the PV is reverse-connection. |
| Manual brake | Wind generator stop turning or slowing turning. |
| Lightning protection | Lightning protection in inside of the controller. |
| Protection grade | IP(Indoor) |
| Insulation resistance | Resistance between DC/AC input and the housing>=50ΜΩ. |
| System parameters | |
| Ambient Temperature & Humidity Range | -20~+55ºC/35~85%RH(No Condensation) |
| Altitude | ≤4000m |
| Dimensions (L*W*H) | 445*425*170mm |
| Net Weight | 11kg |
| Trouble Tapy | Analysis Trouble | Exclude and resolve |
| LCD no dispaly | DC circuit breaker not close between battery and controller. | Closing the breaker |
| The connecting line is insecure between battery and controller | Visual connection,reconnect and Tighten it. | |
| The volage of battery is too low | Check whether the controller paremeter to match the paremeter system or not. | |
| Battery banks have borken,replace them. | ||
| The connecting line is reverse-connection in positive and negative pole between battery and controller. | Replace the fuse of the inner of controller and correct connnect the battery banks. | |
| Not charge | The connecting line of PV mudule and controller is fall off or loose. | Reconnect and tighten the connecting line of system |
| The connecting line is reverse-connection in positive and negative pole between the PV board and controller. | To be corrected reconnect between PV board and controller. |