• Overview
  • Details
  • More
Share Products Categories Channel Cart

1/6
16loops 24loops Reactive Power Factor Compensation Controller for Capacitor Bank图116loops 24loops Reactive Power Factor Compensation Controller for Capacitor Bank图216loops 24loops Reactive Power Factor Compensation Controller for Capacitor Bank图316loops 24loops Reactive Power Factor Compensation Controller for Capacitor Bank图416loops 24loops Reactive Power Factor Compensation Controller for Capacitor Bank图516loops 24loops Reactive Power Factor Compensation Controller for Capacitor Bank图6

16loops 24loops Reactive Power Factor Compensation Controller for Capacitor Bank

Price $20.00
Min Order 1 Piece  
Shipping from Shanghai, China
Quantity
-+
Product details
JKW5C
Power
ISO9001:2000, CCC
All- packaged Type
Low Voltage
1 Uint
Power Plants
PVC
IP56
Huakun
Huakun
Carton Package
113*113mm
Shanghai, China
Product Description
HKK-JKW series of reactive power automatic compensation controller (referred to as controller) is a special equipmentfor low-voltage distribution system to compensate reactive power. It is designed according to the industry standard JB/T9663-2013 and the power standard DL/T597-1996. lts sampling physical quantity is reactive power, with novel design,many functions, good control performance, high reliability advantages, in the domestic similar products in a leadingposition, for distribution automation provides a new equipment.
1.Power supply voltage: rated at 220V or 380V, fluctuation shall not exceed ±10%;
2.Ambient temperature:-25°ºC~55C;
3.Relative humidity: The maximum relative temperature is 90%/(20°c ,4.Altitude: no more than 2000m; 5.Environmental conditions: no explosive inflammable dangerous media,no corrosive metal gases and conductive dustdamaging electrical insulation.
1.Basic parameters Rated voltage: AC380/AC220V±10%
Rated current ACO-5A Rated frequency: 50Hz±5%
2.Measurement accuracy
Voltage: ±1.0%; Current: ±1.0%;
Powerfactor: ±1.0%;
Reactive power:±2.0%.
3.Control parameters
Sensitivity:100mA Target Cos preset: 0.70-1.00; Step 0.01; Factory preset 0.95;
Switching delay: 1-250s; Overvoltage protection: 380-500/230-260v;Step 1 v.Back to the poor 6 V.
Undervoltage protection: 340V/180V; Back to the poor 6v. CT changes: 50/5A-4000/5A Step 1; Capacitance: 0-125kvar each branch factory preset 5Kvar;
Contact capacity: 380V*5A/220V*7A per branch.


Buyer review
Loading review details...
Contact

Shanghai Huakun Electrical Company Ltd.

Audited Supplier3 Years
ProfileCertified by SGS/BV

Message Type

* Content

* Name

* Phone

* Email

* Captcha

captcha

You May Like
Home > Products > Electrical & Electronics > Power Supply & Distribution > Power Distribution Cabinet & Box