PTC-8125D
                        Yes
                        12 Months
                        2400mm
                        <900kg
                        Universal Testing Machine
                        1mA~120A (1mA~200A Optional)
                        0.05/ 0.1/0.2 Class
                        Electronic Load
                        Static Load
                        Digital
                        Computer Control and Manual Control
                        100-500Kg
                        AC50-288V
                        Under
                        0.05 Class
                        Hc3101b Accuracy Class: 0.05 /0.1
                        45Hz~65Hz; Resolution: 0.01Hz
                        24 (12/24/48/60) on Requested
                        Hanpu
                        Standard Wooden Case
                        0.1/0.05 Accuracy Class
                        Zhejiang Jiaxing
                        9030849000
                        
                        Product Description
                    
                                
Single Phase Energy Meter Test Bench is accords with the standard of "IEC 521, 1036, 687and 145 for mechanical meters, IEC 62052-11,IEC 62053-11, 21, 22, 23 for static electronic meters. This bench can be used to test single phase energy meter (up to 0.5 class).
According to the different requirements of customers such as Meter Manufacturer, and provincial metrology centers, we can provide customized, combined flow design, installation, commissioning, and full-time operation and maintenance services with single-phase, three-phase meter test bench.
According to the different requirements of customers such as Meter Manufacturer, and provincial metrology centers, we can provide customized, combined flow design, installation, commissioning, and full-time operation and maintenance services with single-phase, three-phase meter test bench.
| ITEMS | PTC-8125M | PTC-8125E | PTC-8125H | PTC-8320D | PTC-8320E | PTC-8320H | PTC-7100 | |
| Basic functions | Basic error | ○ | ○ | ○ | ○ | ○ | ○ | × | 
| Creeping test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
| Starting test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
| Standard deviation | ○ | ○ | ○ | ○ | ○ | ○ | × | |
| Constant test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
| Meter constant | ○ | ○ | ○ | ○ | ○ | ○ | × | |
| Influence test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
| No load test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
| Max demand test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
| Repeat test | ○ | ○ | ○ | ○ | ○ | ○ | × | |
|   Multi-functions test  | Day time error | ☆ | ☆ | ☆ | ☆ | ☆ | ☆ | × | 
| L/N switching | ☆ | ☆ | ☆ | ☆ | ☆ | ☆ | × | |
| Communication test | ☆ | ☆ | ☆ | ☆ | ☆ | ☆ | × | |
| Power consumption test | ☆ | ☆ | ☆ | ☆ | ☆ | ☆ | × | |
| High voltage | × | × | × | × | × | × | ○ | |